QT-EA® FLOW CENTER
INSTALLATION INSTRUCTIONS
Fig. 1. 26-99 Pump Center Flow Chart
Fig. 2. 26-116 Pump Center Flow Chart
NOTE: Read the entire instruction manual before starting the installation.
WARRANTY
This flow center is warranted for five years from date of sale. Alleged defective product must be returned to B&D Mfg.,
Inc., 901 9th Street, Scranton, Iowa 51462, for inspection via prepaid freight. Defective parts will be repaired or
replaced at the manufacturer’s discretion. No allowance for labor or property damage is implied. Warranty of
performance is limited to the table provided with the unit and only when being used in a closed-loop, heat pump system.
No warranty of performance is provided when pump(s) are provided by others.
INTRODUCTION
These instructions cover the installation of the QT-EA
®
Flow Center Part No. 2-2E-A-SS230QFC, 2-1E-A-SS230QFC and 1
-1E-A-SS230QFC. The QT-EA
®
Flow Center is a prepackaged pumping station to be used with closed-loop, ground source
heat pumps. The package contains a water vessel, an air-eliminating dip tube, a pump protecting check valve, pump(s)
and ball valves that allow the pump(s) to be removed for service without loss of fluid to the system
SAFETY CONSIDERATIONS
Installing and servicing of air conditioning and heating equipment can be hazardous due to system pressures and
electrical components. Only trained, qualified personnel should install, start-up and service this equipment.
Untrained personnel can perform basic maintenance functions such as cleaning coils or cleaning and replacing filters. All
other operations should be performed by trained service personnel.
When working on the equipment, observe precautions in the literature, tags, stickers and labels attached to the
equipment and to any other safety precautions that apply.
Follow all safety codes. Wear safety glasses and work gloves.
B&D Mfg, Inc
901 9th Street
Scranton, IA 51462
Phone (712) 652-3424
Fax (712) 652-3388
www.bdmfginc.com
Patent No. 5,244,037
1
Page view 0
1 2 3 4

Summary of Contents

Page 1 - QT-EA® FLOW CENTER

QT-EA® FLOW CENTER INSTALLATION INSTRUCTIONS Fig. 1. 26-99 Pump Center Flow Chart Fig. 2. 26-116 Pump Center Flow Chart NOTE: Read the entire instruct

Page 2

The recommended piping schematic is usable with all types of closed-loop, ground source heat pump systems, vertical bore holes, horizontal loops, slin

Page 3

3 2. Open the ball valves on both sides of the pumps. 3. Remove the screw on the end of the Grundfos pump motor and rotate the motor shaft with a

Page 4 - Electrical: 1/60/230V

Electrical: 1/60/230V Insulation: Insulated Cabinet Approx. Volume of Fluid: 5 gal. A = 1 1/4" Swivel B = 1 1/4" Union

Comments to this Manuals

No comments